O-IDS-342GT

Industrial 4-port secure serial to Ethernet device server with 4xRS-232/422/485 and 2x10/100/1000Base-T(X)

Features

  • Operating Modes: Virtual Com, Serial Tunnel, TCP Server, TCP Client, UDP, Modbus Gateway
  • Support Modbus Gateway : Modbus TCP, Modbus RTU, Modbus ASCII
  • Security: SSL data encryption; secured management by HTTPS and SSH
  • Event Warning by Syslog, SNMP trap, and Beeper
  • Configurable by Web-based and Windows utility (DS-Tool)
  • Various Windows O.S. supported: Windows NT/2000/ XP/ 2003/VISTA(32/64bit)/ Windows 7(32/64bit)

Specification

Model O-IDS-342GT O-IDS-342GT(+)
Physical Ports   

10/100/1000 Base-T(X) Ports in RJ45

Auto MDI/MDIX
2
PoE P.D. port.  

Present at ETH2
Fully compliant with IEEE 802.3af Power Device specification
Over load & short circuit protection
Isolation Voltage: 1000 VDC min.
Isolation Resistance : 108 ohms min

Serial Ports   
Connector DB9 x 4
Operation Mode RS-232/422/485
Serial Baud Rate 110 bps to 921.6 Kbps
Data Bits 7, 8
Parity odd, even, none, mark, space
Stop Bits 1, 1.5, 2
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND
Flow Control XON/XOFF, RTS/CTS, DTR/DSR
Network Protocol   
Protocol ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP V1/V2c, HTTPS
Jumbo frame Up to 9.6K Bytes
LED Indicators   
Power Indicator

PWR 1(2) / Ready:

Green On: Power is on and functioning Normally.
10/100/1000 RJ45 port indicator

Top Green for port Link at 1000Mbps, Amber for port Link at 100Mbps, off for port Link at 10Mbps Bottom Green for port Link/Act

Serial TX / RX LEDs Red: Serial port is receiving data
Green: Serial port is transmitting data
Power   
Redundant Input power Dual DC inputs. 12-48VDC on 6-pin terminal block
Power Consumption (Typ.) 6.96W
Overload Current Protection Present
Reverse Polarity Protection Present on terminal block
Physical Characteristics   
Enclosure IP-30
Dimensions (W x D x H) 54.2(W)x106.1(D)x145.4(H) mm (2.13x4.18x5.72 inch.)
Weight (g) 740g 745g
Environmental   
Storage Temperature -40 to 85°C (-40 to 185°F)
Operating Temperature -40 to 70°C (-40 to 158°F)
Operating Humidity 5% to 95% Non-condensing
Regulatory Approvals   
EMC EN 55022, EN 55024(CE EMC), EN 50121-4,EN 60945, FCC ,EN 61000-6-2, IEC 61000-3-2 ,IEC 61000-3-3
EMI CISPR 22, EN 55011, FCC Part 15B Class A
EMS

EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8 (PFMF), EN61000-4-11 (DIP)

Shock IEC60068-2-27
Free Fall IEC 60068-2-31 (IEC 60068-2-32)
Vibration IEC60068-2-6
Safety EN60950-1
MTBF 560362 hours

Have Questions? Call +65 6292 0801 or email sales@anewtech.com.sg