ID-InnoAgent EZ2N-0XL1
Module Type: Out-of-Band Remote Management Module, Function: OOB
- Nuvoton NUC980 32bit Microprocessor
- Remote Power On/Off/Reset
- Programmable Remote control GPIO
- Support Remote UART/RS232 Data Transmission
- Support OT Device without Network Connection
- In-Band Heartbeat Agent to Check Device Alive
- Standard MQTT Network Connection Protocol
- Support OTA Firmware Upgrade
- Complies with EN61000-4-2 (ESD) Air-15kV, Contact-8kV
- Operation temperature -40°C to +85°C support
Model | InnoAgent EZ2N-0XL1 |
Module Type | Out-of-Band Remote Management Module |
Function | OOB |
Form Factor | Other |
Host I/F | 3.3V UART, RS232 (Pitch 2.0mm Pin Header) |
Remote Control I/O | 3.3V GPIO x 6, Power SW x2 (Pitch 2.0mm Pin Header) |
Factory Reset | Pitch 2.0mm Pin Header |
Power Source | +5V Standby Power Input (4pin floppy male connector) |
TDP | MAX: 1.125W (5V, 225mA) |
Dimensions (W x L x H/mm) | 51 x 31.3 x 19.05 |
Temperature | Operation: W/T temp: -40°C ~ +85°C Storage: -55°C ~ +95°C |
Environment | Vibration: 5G @7~2000Hz Shock: 50G @ 0.5ms |
InnoAgent is a module that allows out-of-band remote management of systems, even if they have crashed, or are completely offline. Connecting through UART, RS232 or GPIO, InnoAgent acts as a gateway between computer systems and remote management tools to offer a highly available solution for the most important of applications. InnoAgent has two main use cases in the field, as a backup to in-band management for increased availability, or as the only form of remote management, for increased security.
Without InnoAgent, during connection failures, device shut downs, and OS crashes, the device is unable to be monitored remotely through the main device’s LAN port, or Wi-Fi connection.
On devices with an InnoAgent module, even if there is a major issue, whether it be hardware, or software, monitoring applications can still access the device’s information.
Remote commands can also be sent to the device, like power reset. This ability to restart and send other commands to crashed devices eliminates the need to have engineers on site at all times.