O-IES-1041FX

Industrial Slim 5-port Unmanaged Ethernet Switch. 4x10/100Base-T(X) and 1x100Base-FX

Anewtech-Systems-Industrial-Ethernet-Switch-O-IES-1041FX
  • 4x10/100Base-T(X) and 1x100Base-FX single/multi-mode fiber ports
  • Support auto-negotiation and auto-MDI/MDI-X
  • Support store-and-forward transmission
  • Support flow control
  • Support surge protection technology
  • Warning system by relay output
  • Rigid IP-30 housing design
Datasheet
Product Specification
ModelIES-1041FX-MM-SCIES-1041FX-SS-SC
Physical Ports
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX4
Fiber Ports Number11
Fiber Ports Standard100Base-FX100Base-FX
Fiber ModeMulti-modeSingle-mode
Fiber Diameter (μm)62.5/125 μm
50/125 μm
9/125 μm
Fiber Optical ConnectorSCSC
Typical Distance (km)2 km30 km
Wavelength (nm)1310 nm1310 nm
Max. Output Optical Power (dBm)-14 dBm-8 dBm
Min. Output Optical Power (dBm)-23.5 dBm-15 dBm
Max. Input Optical Power (Saturation)0 dBm0 dBm
Min. Input Optical Power
(Sensitivity)
-31 dBm-34 dBm
Link Budget (dB)7.5 dB19 dB
Technology
Ethernet StandardsIEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3x for Flow control
MAC Table2048 MAC addresses
ProcessingStore-and-Forward
LED Indicators
Power IndicatorGreen : Power LED x 2
Fault IndicatorAmber : Indicates PWR1 or PWR2 failure occurred
10/100Base-T(X) RJ45 Port IndicatorGreen for port Link/Act. Amber for Duplex/Collision
Fiber Port LEDGreen for port Link/Act.
Fault Contact
RelayRelay output to carry capacity of 1A at 24VDC
Power
Redundant Input PowerDual DC inputs: 12~48VDC on 6-pin terminal block
Power Consumption (Typ.)5 Watts
Overload Current ProtectionPresent
Reverse Polarity ProtectionPresent
Physical Characteristics
EnclosureIP-30
Dimensions (W x D x H)26.1(W) x 94.9(D) x 144.3(H) mm (1.03 x 3.74 x 5.68 inch.)
Weight (g)378 g
Environmental
Storage Temperature-40 to 85°C (-40 to 185°F)
Operating Temperature-40 to 75°C (-40 to 167°F)
Operating Humidity5% to 95% Non-condensing
Regulatory Approvals
EMIFCC Part 15, CISPR (EN55022) class A
EMSIEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11
ShockIEC60068-2-27
Free FallIEC60068-2-32
VibrationIEC60068-2-6
SafetyEN60950-1