SYS-220TP-HTTR
2U 4-node TwinPro Server. 6 2.5" SATA drives per node, dual 10GbE
Four hot-pluggable systems (nodes) in a 2U form factor. Each node supports the following:
- Dual Socket P+ (LGA-4189) 3rd Generation Intel® Xeon® Scalable Processors
- Intel® C621A chipset
- 16 DIMMs, Up to 4TB 3DS ECC DDR4-3200 LRDIMM/RDIMM
- 2 PCI-E 4.0 x16 (LP), 1 PCI-E 4.0 x8 (with M.2 adapter installed)
- Intel® X710 Dual port 10GBase-T LAN onboard
- 6x 2.5" hot-swap SATA/SAS drive bays
- 4 heavy duty 8cm PWM fans with optimal fan speed control (Per System)
- Two 2200W redundant power supplies with PMBus
- ASPEED AST2600 BMC, 2 USB, VGA. RoT, 2 SATADOM ports
- SATA (6Gbps); 6 slots per node; RAID 0, 1, 5, 10 support.
Datasheet
Product Specification
Product SKU | |
SYS-220TP-HTTR | SuperServer SYS-220TP-HTTR |
Motherboard | Super X12DPT-PT |
Processor/Cache (per Node) | |
CPU | Dual Socket P+ (LGA-4189) 3rd Generation Intel® Xeon® Scalable processors Dual UPI up to 11.2GT/s Support CPU TDP 185W * |
Cores | Up to 32C/64T |
Note | *Please contact us for supporting conditions of high power (TDP 150W and above) or high base frequency (3.0 GHz and above) processors. |
System Memory (per Node) | |
Memory | Memory Capacity: 16 DIMM slots UP to 4TB: 16x 256 GB DRAM Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices (per Node) | |
SATA | SATA3 (6Gbps) via Intel C621A; RAID 0, 1, 5, 10 support |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X710-AT2 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
BMC | ASPEED AST2600 BMC |
Input / Output (per Node) | |
LAN | 1 RJ45 Dedicated IPMI LAN port |
USB | 2 USB 3 port(s) (2 rear) |
Video | 1 VGA port(s) |
DOM | 2 Super DOM (Disk on Module) port |
System BIOS | |
BIOS Type | AMI 32MB SPI Flash EEPROM |
Management | |
Software | Redfish API IPMI 2.0 SSM Intel® Node Manager SPM KVM with dedicated LAN SUM NMI Watch Dog SuperDoctor® 5 |
Power Configurations | ACPI/APM Power Management ACPI Power Management Power-on mode for AC power recovery |
PC Health Monitoring | |
CPU | 5 Phase-switching voltage regulator Monitors for CPU Cores, Chipset Voltages, Memory |
FAN | Fans with tachometer monitoring Pulse Width Modulated (PWM) fan connectors Status monitor for speed control |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
Chassis | |
Form Factor | 2U Rackmount |
Model | CSV-217HQ+-R2K20BP3 |
Dimensions and Weight | |
Height | 3.47" (88mm) |
Width | 17.25" (438mm) |
Depth | 28.75" (730mm) |
Package | 10" (H) x 24.5" (W) x 45" (D) |
Weight | Net Weight: 72 lbs (32.7 kg) Gross Weight: 90 lbs (40.9 kg) |
Available Color | Black front & sliver body |
Front Panel | |
Buttons | Power On/Off button UID button |
LEDs | Network activity LED Power status LED System information (overheat/UID) LED |
Expansion Slots (per Node) | |
PCI-Express (PCI-E) | Slot 1: PCI-E 4.0 x16 LP Slot 2: PCI-E 4.0 x16 LP Internal Slot: M.2 |
Drive Bays / Storage (per Node) | |
Hot-swap | 6x 2.5" hot-swap SATA drive bays |
System Cooling | |
Fans | 4x 8cm heavy duty fans with optimal fan speed control |
Air Shroud | 4 Air Shroud(s) |
Power Supply | 2x 2000W Redundant Power Supplies, Titanium Level |
Total Output Power | 1200W: 100-127Vac 1800W: 200-220Vac 1980W: 220-230Vac 2200W: 220-240Vac (for UL/cUL use only) 2090W: 230-240Vdc (for CCC only) 2090W: 230-240Vac |
Dimension (W x H x L) | 76 x 40 x 336 mm |
AC Input | 50-60Hz |
+12V | Max: 100A / Min: 0A (100Vac-127Vac) Max: 150A / Min: 0A (200Vac-220Vac) Max: 165A / Min: 0A (220Vac-230Vac) Max: 183.3A / Min: 0A (220Vac-240Vac) Max: 174.17A / Min: 0A (230Vac-240Vac) |
5V SB | Max: 1A / Min: 0A |
+54V | Max: 1A / Min: 0A |
Output Type | Backplanes (gold finger) |
Certification | Titanium Level |
Operating Environment | |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |