AS-F1114S-FT
8 Hot-pluggable System Nodes in a 4U Server
8 Hot-pluggable System Nodes in a 4U form factor. Each node supports:
- 1. Single AMD EPYC™ 7003/7002 Series Processor (7003 Series Processor drop-in support requires BIOS version 2.0 or newer)
- Up to 4TB ECC 3DS LRDIMM, up to DDR4-3200MHz; 16 DIMM slots
- 3. Expansion slots: 2 PCI-E 4.0 x16 (LP Riser), 1 PCI-E 4.0 x16 AIOM slot
- AIOM Network card, 1 dedicated IPMI LAN port
- Up to 4 fixed internal 2.5" drive bays: 4 SATA3 by default, or optional 2 NVMe via additional cable
- M.2 Interface: 2 SATA/NVMe, PCI-E 4.0 x4
- M.2 Form Factor: 2260, 2280, 22110
- M.2 Key: M-Key
- 2000W or above Redundant Power Supplies
Product Specification
Product SKU | |
AS -F1114S-FT | A+ Server F1114S-FT |
Motherboard | Super H12SSFF-AN6 |
Processor/Chipset (per Node) | |
CPU | Single AMD EPYC™ 7003/7002 Series Processor (7003 Series Processor drop-in support requires BIOS version 2.0 or newer) Socket SP3 Supports CPU TDP / cTDP up to 280W* |
Cores | Up to 64 Cores |
Note | * Certain CPUs with high TDP may be supported only under specific conditions. |
System Memory (per Node) | |
Memory Capacity | 16 DIMM slots Supports up to 4TB Registered ECC DDR4 3200MHz SDRAM in 16 DIMMs 8-channel memory bus |
Memory Type | DDR4 3200 MHz Registered ECC, 288-pin gold-plated DIMMs |
Memory Sizes | 8GB, 16GB, 32GB, 64GB, 128GB, 256GB |
Memory Voltage | 1.2V |
Error Detection | Corrects single-bit errors Detects double-bit errors (using ECC memory) |
On-Board Devices | |
Chipset | System on Chip |
SATA | SATA3 (6Gbps) |
Network Controllers | Flexible networking via AIOM (not included, must add 1 per node) |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Graphics | ASPEED AST2600 BMC |
Input / Output (per node) | |
SATA | 4 SATA3 (6Gbps) ports |
LAN | Flexible networking via AIOM 1 RJ45 Dedicated IPMI LAN port |
USB | 2 USB 3.0 ports (front) |
VGA | 1 VGA port (front) |
Others | 1 TPM 2.0 header |
System BIOS | |
BIOS Type | 256Mb SPI Flash EEPROM with AMI BIOS |
Management | |
Software | IPMI 2.0 KVM with dedicated LAN SSM, SUM SuperDoctor® 5 Watch Dog |
Power Configurations | ACPI Power Management |
PC Health Monitoring | |
CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 7 Phase-switching voltage regulator |
FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
Chassis | |
Form Factor | 4U Rackmount |
Model | CSE-F418IF4-R2K20BP |
Dimensions and Weight | |
Width | 17.63" (448mm) |
Height | 6.96" (177mm) |
Depth | 29" (737mm) |
Package | 28.3" (W) x 15.0" (H) x 42.4" (D) |
Weight | Net Weight: 108.5 lbs (49.21 kg) Gross Weight: 204.8 lbs (90.71 kg) |
Available Colors | Black |
Front Panel (per node) | |
Buttons | Power On/Off button UID button |
LEDs | Power status LED Hard drive activity LED Network activity LEDs Information LED (UID, Fan failure, Overheat) |
Expansion Slots (per node) | |
PCI-Express | 2 PCI-E 4.0 x16 (Low-profile riser) 1 PCI-E 4.0 x16 (AIOM) |
Drive Bays (per node) | |
Fixed | Up to 4 internal 2.5" drive bays: 4 SATA3 by default, or optional 2 NVMe via additional cable in Optional Parts List |
M.2 | M.2 Interface: 2 SATA/NVMe, PCI-E 4.0 x4 M.2 Form Factor: 2260, 2280, 22110 M.2 Key: M-Key |
System Cooling | |
Fans | 8 heavy-duty 8cm 13.5k RPM rear fans per enclosure |
Power Supply | 2000W or above Redundant Power Supplies with PMBus |
Total Output Power and Input | 1100W with Input 100-120Vac 1400W with input 120-140Vac 1800W with input 200-220Vac 1980W with input 220-230Vac 2000W with input 230-240Vac 2000W with input 200-240Vac (for UL/cUL use only) |
AC Input Frequency | 50-60Hz |
Dimension (W x H x L) | 76 x 40 x 336 mm |
+12V | Max: 91.7A / Min: 0A (100-120Vac) Max: 116.7A / Min: 0A (120-140Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 166.7A / Min: 0A (230-240Vac) Max: 166.7A / Min: 0A (200-240Vac) (for UL/cUL use only) |
5VSB | Max: 1A / Min: 0A |
Output Type | Backplanes (gold finger) |
Operating Environment | |
RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
FatTwin® Advanced 4U Twin Architecture with 8 and 4 Nodes
The innovative FatTwin architecture provides flexibility and system accessibility for unique datacenter requirements with front or rear I/O, as well as electrically isolated, modularized left/right nodes with redundant power supplies for maximum reliability.
- Highly modular multi-node (4U 8-Node or 4U 4-Node) systems with tool-less design and independent backplanes built-in per node to eliminate a single point of failure
- Front or Rear I/O accessible service design depending on data center environments
- All-hybrid drive bays - NVMe, SAS, or SATA
Leading Multi-node Architecture with Front or Rear I/O
FRONT OR REAR I/O TWIN ARCHITECTURE TO MAXIMIZE SERVICEABILITY AND RELIABILITY
- Single AMD EPYC™ 7003/7002 Series Processor* (TDP up to 280W) per node
- Flexible AIOM networking
- Electrically isolated Redundant Titanium Level power supplies per side (2 left, 2 right)
AS-F1114S-FT4U Front I/O System with 8 Hot-pluggable Single-Processor Server Nodes with 2-4x 2.5" SATA3/NVMe drives per node
AS-F2014S-RNTR 4U Rear I/O System with 4 Hot-pluggable Single-Processor Server Nodes with 8x 3.5” drives and 4x M.2 per node
AS-F1114S-RNTR 4U Rear I/O System with 8 Hot-pluggable Single-Processor Server Nodes with 6x 2.5” drives and 4x M.2 per node