AS-F1114S-RNTR
8 Hot-pluggable System Nodes in a 4U Server
8 Hot-pluggable System Nodes in a 4U form factor. Each node supports:
- Single AMD EPYC™ 7003/7002 Series Processor (7003 Series Processor drop-in support requires BIOS version 2.0 or newer)
- Up to 2TB ECC 3DS LRDIMM, up to DDR4-3200MHz; 8 DIMM slots
- Expansion slots: 1 PCI-E 4.0 x16 (LP Riser), 1 PCI-E 4.0 x16 (for AIOM)
- AIOM Network card,1 dedicated IPMI LAN port
- 6 Hot-swap 2.5" drive bays: 2 NVMe/SATA3, 4 SATA3 (optional NVMe)
- M.2 Interface: 4 SATA/PCI-E 4.0 x4
- M.2 Form Factor: 2242, 2260, 2280, 22110
- M.2 Key: M-Key
- 2200W Redundant Power Supplies Titanium Level (96%)
Product Specification
Product SKU | |
AS -F1114S-RNTR | A+ Server F1114S-RNTR (Black) |
Motherboard | Super H12SSFR-AN6 |
Processor/Chipset (per Node) | |
CPU | Single AMD EPYC™ 7003/7002 Series Processor (7003 Series Processor drop-in support requires BIOS version 2.0 or newer) Socket SP3 Supports CPU TDP / cTDP up to 280W* |
Cores | Up to 64 Cores |
Note | * Certain CPUs with high TDP may be supported only under specific conditions. |
System Memory (per Node) | |
Memory Capacity | 8 DIMM slots Supports up to 2TB Registered ECC DDR4 3200MHz SDRAM in 8 DIMMs 8-channel memory bus |
Memory Type | DDR4 3200 MHz Registered ECC, 288-pin gold-plated DIMMs |
Memory Sizes | 8GB, 16GB, 32GB, 64GB, 128GB, 256GB |
Memory Voltage | 1.2V |
Error Detection | Corrects single-bit errors Detects double-bit errors (using ECC memory) |
On-Board Devices | |
Chipset | System on Chip |
SATA | SATA3 (6Gbps) |
Network Controllers | Flexible networking via AIOM (not included, must add 1 per node) |
IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
Graphics | ASPEED AST2600 BMC |
Input / Output (per node) | |
LAN | Flexible networking via AIOM 1 RJ45 Dedicated IPMI LAN port |
USB | 2 USB 3.0 ports (rear) |
VGA | 1 VGA port |
Others | 1 COM port 1 TPM 2.0 header |
System BIOS | |
BIOS Type | 256Mb SPI Flash EEPROM with AMI BIOS |
Management | |
Software | IPMI 2.0 KVM with dedicated LAN SSM, SUM SuperDoctor® 5 Watch Dog |
Power Configurations | ACPI Power Management |
PC Health Monitoring | |
CPU | Monitors for CPU Cores |
FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
Chassis | |
Form Factor | 4U Rackmount |
Model | CSE-F418BC3-R2K20B |
Dimensions and Weight | |
Width | 17.63" (448mm) |
Height | 6.96" (177mm) |
Depth | 29" (737mm) |
Package | 28.3" (W) x 15.0" (H) x 42.4" (D) |
Weight | Net Weight: 150 lbs (68.04 kg) Gross Weight: 200 lbs (90.71 kg) |
Available Colors | Black |
Front Panel (per node) | |
Buttons | Power On/Off button UID button |
LEDs | Power status LED Hard drive activity LED Network activity LEDs Information LED (UID, Fan failure, Overheat) |
Expansion Slots (per node) | |
PCI-Express | 1 PCI-E 4.0 x16 (Low-profile riser) 1 PCI-E 4.0 x8 (Internal RAID AOC) |
Drive Bays (per node) | |
Hot-swap | 2 Hot-swap 2.5" NVMe/SATA3 and 4 SATA3 (optional NVMe) drive bays |
M.2 | M.2 Interface: 4 SATA/PCI-E 4.0 x4 M.2 Form Factor: 2242, 2260, 2280, 22110 M.2 Key: M-Key |
Backplane | 1 SATA/NVMe backplane |
System Cooling (per node) | |
Fans | 3x 4cm 17.6K RPM middle fans |
Power Supply | 2200W Redundant Power Supplies with PMBus |
Total Output Power and Input | 1200W with Input 100-127Vac 1800W with Input 200-220Vac 1980W with Input 220-230Vac 2090W with Input 230-240Vac 2200W with Input 220-240Vac (for UL/cUL use only) 2090W with Input 230-240Vdc (for CCC only) |
AC Input Frequency | 50-60Hz |
Dimension (W x H x L) | 76 x 40 x 336 mm |
+12V | Max: 100A / Min: 0A (100-127Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 174.17A / Min: 0A (230-240Vac) Max: 183.3A / Min: 0A (220-240Vac) |
5VSB | Max: 1A / Min: 0A |
Output Type | Backplanes (gold finger) |
Operating Environment | |
RoHS | RoHS Compliant |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
FatTwin® Advanced 4U Twin Architecture with 8 and 4 Nodes
The innovative FatTwin architecture provides flexibility and system accessibility for unique datacenter requirements with front or rear I/O, as well as electrically isolated, modularized left/right nodes with redundant power supplies for maximum reliability.
- Highly modular multi-node (4U 8-Node or 4U 4-Node) systems with tool-less design and independent backplanes built-in per node to eliminate a single point of failure
- Front or Rear I/O accessible service design depending on data center environments
- All-hybrid drive bays - NVMe, SAS, or SATA
Leading Multi-node Architecture with Front or Rear I/O
FRONT OR REAR I/O TWIN ARCHITECTURE TO MAXIMIZE SERVICEABILITY AND RELIABILITY
- Single AMD EPYC™ 7003/7002 Series Processor* (TDP up to 280W) per node
- Flexible AIOM networking
- Electrically isolated Redundant Titanium Level power supplies per side (2 left, 2 right)
AS-F1114S-FT4U Front I/O System with 8 Hot-pluggable Single-Processor Server Nodes with 2-4x 2.5" SATA3/NVMe drives per node
AS-F2014S-RNTR 4U Rear I/O System with 4 Hot-pluggable Single-Processor Server Nodes with 8x 3.5” drives and 4x M.2 per node
AS-F1114S-RNTR 4U Rear I/O System with 8 Hot-pluggable Single-Processor Server Nodes with 6x 2.5” drives and 4x M.2 per node